Operation and management of refrigeration equipment
1. As the evaporation temperature decreases, the compression ratio of the compressor increases, and the energy consumption per unit cooling capacity increases. When every 1 ℃ below the evaporation temperature, more power consumption 3% - 4%. Therefore, it is possible to reduce the evaporation temperature difference and increase the evaporation temperature, not only saving electricity consumption, but also increasing the relative humidity between the cold.
2. As the condensing temperature increases, the compression ratio of the compressor increases, and the energy consumption per unit cooling capacity increases. Condensation temperature between 25 ℃ and 40 ℃, every increase 1 ℃, increase power consumption by around 3.2%.
3. When the heat exchange surface of the condenser and evaporator is covered with oil layer, the condensation temperature will increase and the evaporation temperature will decrease, leading to the reduction of cooling production and the increase of electricity consumption. When 0.1mm thick oil layer is accumulated on the inner surface of the condenser, the cooling capacity of the compressor will decrease by 16.6 and the electricity consumption will increase by 12.4. Within the evaporator surface product 0.1 mm thick oil reservoir, in order to maintain constant low temperature requirements, evaporation temperature is 2.5 ℃, power consumption increased by 9.7.
4. When the air is concentrated in the condenser, the condensing pressure will increase, and when the non-condensing gas partial pressure reaches 1.96105Pa, the power consumption of the compressor will increase by 18.
5, when the wall form scum of condenser is 1.5 mm, condensation temperature than the scale before the temperature increased 2.8 ℃, power consumption increased by 9.7.
6, evaporator surface covering a layer of frost layer, reduce the heat transfer coefficient, especially when the surface frosting finned tube, not only increase the heat transfer resistance, but also difficult to make the air flow between the fin and reduce the appearance of the heat transfer coefficient and heat dissipation area. When indoor temperature is lower than 0 ℃, 10 ℃ temperature difference on both sides of the evaporator pipe, evaporator work after a month, the heat transfer coefficient is about frost before 70.
7. The gas inhaled by the compressor is allowed to be over-heated to a certain extent, but the over-heat is too high, and the specific volume of the gas inhaled increases, its cooling capacity decreases, and the relative power consumption increases.
8. When the compressor is frosting, quickly close the small air suction valve, sharply reduce the cooling capacity and increase the relative power consumption.
From the above analysis, it can be seen that good operation management of refrigeration equipment is an important link to improve the economic benefits of refrigeration system.
Ii. Energy-saving measures for refrigeration operation
We will strengthen the management of equipment operations and establish a system for electricity management and statistics on single consumption. We will increase the necessary measuring instruments and instruments, carry out energy conservation and technological transformation, and consolidate the work of energy conservation from the system.
1. Properly control and adjust the amount of liquid supplied by the system, and avoid excessive humidity and overheating of the compressor after inhalation.
2. Choose the number of compressor running stations reasonably, so that its refrigeration capacity matches the thermal load of the system.
3. Adjust the number of operating platforms of the fan and water pump according to the process requirements and the change of external temperature.
4. Regularly release oil and air, remove frost and scale, maintain good heat transfer effect of the equipment, and avoid excessive condensation pressure and low evaporation pressure.
3. Improve working conditions of refrigeration equipment
1. Improve the water quality, slow down the scaling, improve the condensing effect of the condenser, and reduce the condensing temperature.
2. When the load rate of motors of refrigeration equipment is lower than 0.4, the motors can be changed from being exposed to Y, so as to improve the power factor. Moreover, it is required to make automatic switching between them.
3. Use automatic control operation instead of manual operation as far as possible, so as to realize the operation of the refrigeration system in the best working condition, which can save 5-15% of electricity.
The last one:The advantages and disadvantages of various chiller are summarized
Next:The role of these components in cold storage construction?

Return list

Recommended for you

  • Mobile web site

  • The official WeChat

版權(quán)所有: 江蘇利邦機(jī)電設(shè)備有限公司 Copyright ? 2018 蘇ICP備18027510號(hào)-1

主站蜘蛛池模板: 国产午夜福利久久精品| 福利一区二区三区视频在线观看| 日韩精品久久久肉伦网站| 亚洲av无码乱码国产精品久久| 久久久久亚洲av片无码v| 解开警花的裙子猛烈进入| 亚洲av无码片在线观看| 无码精品黑人一区二区三区| 337p日本欧洲亚洲大胆人人| 亚洲 日韩 激情 无码 中出| 国产一区二区三区美女| 精品蜜臀久久久久99网站| 亚洲av无码一区二区一二区潮浪| 奇米777国产在线视频| 国产免费观看av大片的网站| 色综合久久久久综合99| 亚洲av无码久久忘忧草| 成人性生交片无码免费看| 亚洲的天堂av无码| 亚洲乱码无码永久不卡在线| 国产超碰人人模人人爽人人喊 | 亚洲乱码一区av春药高潮| 国产精品爽爽va在线观看网站| 亚洲av无码一区二区三区国产| 国产在线aaa片一区二区99| 综合亚洲另类欧美久久成人精品 | 久久精品免费一区二区喷潮| 不卡av电影在线| 亚洲av蜜桃永久无码精品| 亚洲av永久无码精品三区在线| 欧美综合自拍亚洲综合图片区| 高雅人妻被迫沦为玩物电影bd| 四虎亚洲精品成人a在线观看| 亚洲va欧美va天堂v国产综合 | 俺去啦最新地址| 国产中老年妇女精品| 欧美一夜爽爽爽爽爽爽| 99久久人妻精品免费二区| 色老板精品视频在线观看| 久久久噜噜噜久久中文字幕色伊伊 | 大地资源在线播放观看mv|